Monessen Hearth HVFL18 Manuale Utente

Pagina di 44
18 
59D1015
Damper Stop
Damper
Figure 13 - Damper Stop Installation.
(See WARNING at top of next page.)
FIREPLACE PREPARATION
BEFORE FULLY INSTALLING THE UNIT:
  •  Turn OFF the gas supply to the fireplace or firebox.
  •  Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting 
may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.
INSTALLING VENTED APPLICATIONS
Manual and milli-volt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 
and National Fuel Gas Code, Section 6.6. Since, the gas logs are operated with the damper open, non-combustible mate-
rial and minimum mantel requirements do not apply.
BEFORE INSTALLING THE APPLIANCE:
  •  Turn off gas supply to fireplace or firebox.
  •   Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions. 
Have this cleaning performed annually after installation.
  •  Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot 
outage or sooting. Use a heat-resistant sealant. 
Install and operate the appliance as directed in this manual.
DAMPER STOP INSTALLATION:
A damper stop must be provided with the unit. Contact 
your dealer to obtain one. The damper stop must be 
installed as shown in Figure 13 to prevent full closure 
of the fireplace damper blade and provide a minimum 
29 square inch flue opening.
Before installing in a solid fuel burning 
fireplace, The chimney flue and firebox 
must  be  cleaned  of  soot,  creosote, 
ashes  and loose paint by a qualified 
chimney cleaner. 
W
ARNING
This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace 
or  manufactured  fireplace)  with  a  working  flue  and  constructed  of  noncombustible 
material.
Exception:  
DO  NOT  install  this  appliance  in  a  factory-built  fireplace  that  includes 
instructions stating that it has not been tested or should not be used with unvented 
gas logs. This log set may be installed as a vented log set. 
W
ARNING