2.  Assemble and Adjust the Sleeve Length 
Measure wall thickness through previously drilled 
3 1/2 inch (90 mm) hole. 
The end of the sleeve should protrude 3/16 - 3/8 
inch (5-10 mm) from the outside wall. 
In the “A” vent kit there are 4 parts provided with 
which to assemble the sleeve.  Use the table to 
determine which pieces to assemble.   
In both the “A” and “B” vent kits, two parts are 
threaded for additional adjustment.   
Adjust the sleeve length to wall thickness plus 
3/16 - 3/8 inch (5-10 mm). 
  Flue Manifold Installation   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Disassemble the Flue Manifold  
The flue consists of 3 parts:  
•  sleeve 
•  inside connection 
•  terminal 
Disassemble the flue manifold by first pulling 
out the inside connection.  To remove the 
outer terminal pull and release the two 
internal ties and then pull out the outer 
terminal.    
Clearance to combustibles for the sleeve and 
flanges is zero inches. 
  Drilling Flue and Gas Supply Holes   
 
 
 
 
 
 
 
 
 
 
 
 
Check for water and gas pipes as well as electric 
cables.  Use the template supplied to mark the wall 
locations for the flue manifold and the gas supply.  
Drill the flue hole using a 3 1/2 inch (90 mm) drill.   
For weatherboard walls, drill through the center of the 
weatherboard from the outside first and then through 
the plasterboard.   
Inside Connection 
Sleeve 
Terminal 
Sleeve Parts 
a
b
c
For wall thickness plus 3/16 - 3/8 in (5-10 mm) 
Assemble these parts (“A” Vent Kit) 
4 1/3 - 6 1/8 in (110 - 155 mm) 
 
6 1/8 - 7 3/4 in (155 - 195 mm) 
 
7 3/4 - 9 1/2 in (195 - 240 mm) 
 
a
b
+
a
b
c
+
+
a
b
c
+
+
c
+