January 30, 2004
5100-I  WOOD INSERT
R
250-1960  Rev B
SERIAL NUMBER LABEL LOCATION:
ON RIGHT SIDE OF INSERT AS YOU FACE THE APPLIANCE
In Canada a full length 6” (152mm) S635 flue liner required 
as per ULC S628.
NOTE:  When installling into a masonry fireplace, the fire-
place must be built to UBC Chapter 37 standards.  Do not 
remove brick or mortar from masonry fireplace to accomo-
date insert.  The permanent metal warning plate provided 
must be attached to the back of the fireplace stating the fire-
place may have been altered to accomodate the insert and 
must be returned to original condition for use as a conven-
tional fireplace.
CLEARANCES TO COMBUSTIBLES
United States and Canada
Hearth Extension 
A
B
C
D
F
E
Insert
Side
W
all 
Fascia or Trim 
Mantel 
 
 
INSTALLATION:   Masonry, Heat Circulating and *Zero Clearance
 
 
12" (305) 
40" (1016) 
35" (889) 
7" (178) 
16" (406) 
8"(200) 
 
 
 
 
 
 
18" (457) Canada
With 5" Mantel Deflector, Part No. 831-1520
 
  12" (305) 
29" (737) 
20" (889) 
7" (178) 
16" (406) 
8"(200) 
 
 
 
 
 
 
18" (457) Canada
 
With 8" Mantel Deflector, Part No. 831-1530
 
  12" (305) 
23" (585) 
16" (406) 
7" (178) 
16" (406) 
8"(200) 
 
 
 
 
 
 
18" (457) Canada
*Zero Clearance in USA Only.
THERMAL PROTECTION USA & CANADA
Thermal protection must be 1 inch (25mm) minimum thickness (“k” value = 0.84) or equivalent material.  
See Alternate Floor Protection Work Sheet on page 7.