Enviro Omega Manuale Utente

Pagina di 16
Figure 9: Omega Burn Heat Exchanger Cleaning.
11
Routine Cleaning and Maintenance
HEAT EXCHANGER TUBES (Weekly)
There are two (2) sets of exchanger tube scrapers; the 
handles are located under the top grill (trivet). Lift the 
grill and move the handles all the way up and down a 
few  times  (ONLY  WHEN  THE  UNIT  IS  COLD)  in  order 
to  clean  away  any  fly  ash  that  may  have  collected  on 
the heat exchanger tubes. As different types of pellets 
produce different amounts of ash, cleaning of the tubes 
should be done on a regular basis to enable the unit to 
run efficiently.
DOOR GLASS CLEANING (Weekly) 
Cleaning of the glass must only be done when stove is 
cold. Open the door by lifting the handle. The glass can 
be cleaned by wiping down the outside and inside of the 
glass with a dry soft cloth. 
If the glass has build up that can not be removed with 
only  the  cloth,  clean  the  glass  using  paper  towel  and 
a  gas  appliance  glass  cleaner,  this  may  be  purchased 
through most dealers. If a gas appliance glass cleaner is not available, use a damp paper towel dipped 
in fly ash to clean the glass. After the glass has been cleaned use the dry soft cloth to wipe down the 
outside and inside of the glass. 
ASH PAN AND DOOR GASKETS (Weekly)
After  extended use the gasketing may come loose. To repair this, glue the gasketing on using high-
temperature  fiberglass  gasket  glue  available  from  your  local  dealer.  This  is  important  to  maintain  an 
airtight assembly. 
ASH BOX (Weekly)
IMPORTANT: The unit must be OFF while the ash pan is removed.
The ash box is located behind the lower door (see Figure 10). To remove the ash box, lift the latch on the 
right, open the ash box door, and lift it out.  
Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. 
Remember that different pellet fuels will have different ash contents. Ash content is a good indication of 
fuel efficiency and quality.  Refer to “S
AFETY
 W
ARNINGS
 A
ND
 R
ECOMMENDATIONS
” for disposal of ashes. Vacuum 
the inside of the ash pan compartment inside the pedestal including the hole at the top back of the 
compartment. Insert the ash box fully and close ash box door. 
DO NOT PLACE UNBURNED OR RAW PELLET FUEL IN ASH PAN.
EXHAUST VENT (Biannually)
This vent should be cleaned every year or after two tons of pellets. We recommend contacting your 
dealer for professional cleaning.  To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash.  
Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as 
possible.
FRESH AIR INTAKE (Biannually)
Inspect periodically to be sure that it is not clogged with any foreign materials.