2.5. Adjusting airflow direction
The vertical air vane helps select the vertical direction of the airflow.
1
Press AIR DISCHARGE button to select the vertical airflow direction.
• Each time you press the button, the option changes are displayed on the remote
controller, as shown below.
A (swing) 
→ B → C → D → E → A
• In cooling/drying mode with the fan speed set to LOW, every press on the button
will change the direction in the order of A, B, D, A.  (C can not be set)
• If D or E is set, the angle will automatically revert to B after one hour of operation.
(Do not use D and E too often in cooling/drying mode with the fan speed set to
LOW, or condensation or dripping can occur.)
 F “AUTO RETURN” should be displayed.
• When the angle setting is C in cooling mode, switching the fan speed from HIGH
to LOW will cause the angle to revert to B automatically.
• The airflow direction can not be set with UP/DOWN while the SWING setting is being used.
• The arrow indicators are alternately displayed when the air sweep is in operation,
however they are not displayed when the air sweep is not in operation.
• The left/right guide vanes of PC(H) series and the guide vane of the PK(H)  serises
can be changed manually.
2.6. Using the timer
1)
Set the current time
1
Press clock/timer button to display the “CLOCK” B.
Remote
CLOCK
AUTO
START
AUTO
STOP
→ No Display
controller display A
2
Each time you press 
TIMER SET
 button, the time increases in increments of one minute.
Each time you press 
TIMER SET
 button, the time decreases in increments of one minute.
• Press and hold the button to rapidly change the time.
• The time changes in increments of one minute 
→ ten minutes → in units of hour; in
this order.
• Approximately ten seconds after pressing the button, the display on the remote
controller will turn off.
(For Wireless Remote Controller)
1
Press the CLOCK button using a thin stick and blink the time A.
2
Press the 
h
 and 
min
 button to set the current time.
3
Press the CLOCK button using a thin stick.
2)
Set the time to start the unit as follows
1
Press clock/timer button to display B 
AUTO
START
.
2
Press 
TIMER SET
 button to set the time that you want the unit to start.
The start time is displayed at A.
(For Wireless Remote Controller)
1
Press the 
AUTO START
 button.
• Time can be set while the following symbol is blinking.
ON time : B START is blinking.
2
Use the 
h
 and 
min
 buttons to set the desired time.
3
To cancel the ON timer, press the 
AUTO START
 button.
3)
Set the time to stop the unit as follows
1
Press clock/timer button to display C 
AUTO
STOP
.
2
Press 
TIMER SET
 button to set the time that you want the unit to stop.
The stop time is displayed at A.
(For Wireless Remote Controller)
1
Press the 
AUTO STOP
 button.
• Time can be set while the following symbol is blinking.
OFF time : C STOP is blinking.
2
Use the 
h
 and 
min
 buttons to set the desired time.
3
To cancel the OFF timer, press the 
AUTO STOP
 button.
4)
Changing the set times
1
Press clock/timer button to display the time (CURRENT, START, STOP) you want
to change.
2
Press 
TIMER SET
 button to set the desired time.
• When change is made to either one of a pair, e.g., AUTO START or AUTO STOP,
set the time you need not to change to 
.  This display is available following
23:50.
(For Wireless Remote Controller)
Press the 
AUTO START
 or 
AUTO STOP
 to cancel the timer and repeat from 2) or 3).
A
B
C
D
E
A
B
C
D
E
PL(H)
Swing
30°
45°
55°
70°
PK(H)*
Swing
10°
30°
60°
70°
PK12FK3
10°
30°
60°
70°
PC(H)
Swing
100% Horizontal
20°
40°
60°
* Except PK12FK3
ON/OFF
  TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
1
ON/OFF –
TIMER SET
SET TEMP.
REMOTE CONTROLLER
MODE
TIMER ON/OFF CLOCK/TIMER
FAN SPEED AIR DISCHARGE
FILTER
AIR SWEEP
CHECK
TEST RUN
STAND BY 
DEFROST
DRY COOL
AUTO FAN
HEAT
CENTRALLY CONTROLLED
˚F
SWING
FAN
SPEED
AUTO
RETURN
NOT AVAILABLE
˚F
CHECK MODE
FILTER
TIMER
TEST RUN
TIMER OFF
CLOCK AUTO AUTO
CHECK SET TEMP.
START STOP
B
1
2
A
ON/OFF
  TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
A
2
13
ON/OFF –
TIMER SET
SET TEMP.
REMOTE CONTROLLER
MODE
TIMER ON/OFF CLOCK/TIMER
FAN SPEED AIR DISCHARGE
FILTER
AIR SWEEP
CHECK
TEST RUN
STAND BY 
DEFROST
DRY COOL
AUTO FAN
HEAT
CENTRALLY CONTROLLED
˚F
SWING
FAN
SPEED
AUTO
RETURN
NOT AVAILABLE
˚F
CHECK MODE
FILTER
TIMER
TEST RUN
TIMER OFF
CLOCK AUTO AUTO
CHECK SET TEMP.
START STOP
A BC
1
2
ON/OFF
  TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
C
13
A
B
2