Mitsubishi Electronics 36FK3 Manuale Utente

Pagina di 12
7
PLH18AK
PLH24AK
PLH30AK
PLH36AK
PLH42AK
18,000
24,000
30,000
35,400
42,000
19,000 [24,500/25,500]
26,000 [31,500/32,500]
33,000 [39,500/41,200]
38,000 [45,900/47,600]
44,300 [52,200/53,900]
11,000 [16,500/17,500]
16,500 [22,000/23,000]
18,500 [25,000/26,700]
23,000 [30,900/32,600]
26,800 [34,700/36,400]
1.75
2.57
3.17
3.63
3.98
1.59 [3.19/3.49]
2.51 [4.11/4.41]
3.04 [4.94/5.44]
3.45 [5.75/6.25]
3.82 [6.12/6.62]
1.32 [2.92/3.22]
2.15 [3.75/4.05]
2.55 [4.45/4.95]
2.93 [5.23/5.73]
3.24 [5.54/6.04]
10.5
10.3
10.4
10.0
10.7
7.2
7.0
6.9
7.1
7.0
PLH18AK
PLH24AK
PLH30AK
PLH36AK
PLH42AK
Munsell 0.7Y  8.59/0.97
208/230,  1,  60
20
25
15
17
0.7
1.2
1.4
7.7/8.3 [1.6/1.9]
9.1/10.4 [1.9/2.4]
11.1/12.2 [2.3/2.8]
530-710
710-990
780-1060
490-670
670-950
740-1020
33-1/16
33-1/16
10-3/16
11-3/4
37-3/8
37-3/8
1-3/16
57
71
75
11
PUH18EK
PUH24EK
PUH30EK
PUH36EK
PUH42EK7
Munsell 5Y 7/1
208/230,  1,  60
20
30
40
16
20
22
28
0.75
0.65+0.65
0.75+0.75
0.8+0.8
RH247NAB
NH33NBD
NH41NAD
NH47NAD
ZR42K3-PFV
12.0
11.5
14.0
17.5
20.4
37
54
73
87
109
0.11/0.17 (23/28)
0.16/0.17 (33/39)
Capillary tube
Reverse cycle
34-1/4
38-3/16
11-5/8
13-9/16
33-1/2
49-9/16
131
202
245
246
246
With grille
Indoor unit-remote controller DC12V, Indoor unit- outdoor unit DC12V
Cooling
*1  BTU/h
Capacity
Heating
*1,*3  BTU/h
Heating
*2,*3  BTU/h
Cooling
*1  kW
Heating
*1,*3  kW
Heating
*2,*3  kW
SEER
HSPF
INDOOR UNIT MODELS
External finish
Power supply
V, Phase, Hz
Max. fuse size (time delay)
A
Min. ampacity
A
Fan motor
F. L. A.
Auxiliary heater
A (kW)
Airflow
Dry
CFM
Lo-Hi
Wet
CFM
W
in
Dimensions D
in
H
in
W
in
Dimensions
D
in
(GRILLE)
H
in
Weight
lbs
Weight (GRILLE)
lbs
OUTDOOR UNIT MODELS
External finish
Power supply
V, Phase, Hz
Max. fuse size (time delay)
A
Min. ampacity
A
Fan motor
F. L. A.
Models
Compressor
R. L. A.
L. R. A.
Crankcase heater
A (W)
Refrigerant control
Defrost method
W
in
Dimensions D
  in
H
in
Weight
lbs
REMOTE CONTROLLER
Control voltage
(by built-in transformer)
Item
Models
Power
consumption
NOTES:
*1 Rating conditions (cooling) – indoor: 80°F DB. 67°F WB
outdoor: 95°F DB. 75°F WB
(heating) – indoor: 70°F DB. 60°F WB
outdoor: 47°F DB. 43°F WB
*2 Rating conditions (heating) – indoor: 70°F DB. 60°F WB
outdoor: 17°F DB. 15°F WB
*3 Heating capacity and power consumption in [  ] include auxiliary electric heater operation at 208/230V.
Units should be installed by licensed electric contractor accordingly to local code requirement.
* Specifications subject to change without notice.
5. Specifications