3.2 INSTALLATION
• Pick a location which will allow the conditioned air to blow
into the area you want. Good installation with special
attention to the proper position of the unit will lessen the
chance that service will be needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused parts
HOW TO INSTALL
Before installing the unit, identify the existing wall sleeve
from the list below.
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition and have a
rear grille that securely attaches to  sleeve, or rear flange that
serves as a stop for the Air Conditioner.
Remove old air conditioner from existing wall sleeve.
Clean the interior of an existing sleeve.
(Do not disturb seals.)
Wall sleeve must be securely fastened in wall before
installing the air conditioner. Use the nails or screws
through sleeve into wall, if needed. Repaint sleeve if
needed.
Prepare the wall sleeve for installation of the unit. If you
plan to use your existing wall sleeve, and it is not
FRIEDRICH, use procedure B or C below.
Install new unit into wall sleeve.
CAUTION: When installation is completed, replacement unit
MUST have a rearward slope as shown. To achieve 1/4"
slope, remove the backing from the 11-13/16" shim strips and
attach them as shown below in Fig. 19. Place the higher
portion of shim to the front of the rib on base of wall sleeve. 
1
2
3
4
5
6
1/4" 
Wall Sleeve
FRONT
UNIT
SHIM PLACEMENT
UNIT INSTALLATION 
1" high
3/4" High
Shim 
6"
6"
FIG. 19
Installing the 
Heat Controller sleeve ensures
optional performances of the unit.
If you decide to keep the existing wall sleeve, you have
to redirect the louvers at the back of the wall sleeve.
Refer to FIG. 23 on p15. The use of pliers is
recommended. If you DO NOT redirect, you run the risk
of poor performance  or premature product failure. This
is not covered under the terms of the  
Heat Controller
warranty.
Procedure
Brand
Depth(inches)
A(page 16)
FRIEDRICH USC
16-23/32
White-Westinghouse
Frigidaire Carrier 
16, 17-1/2
(52F series)
or 22
General Electric
16-7/8
/Hotpoint
Whirlpool
17-1/8 or 23
Carrier (51S series)
18-5/8
Fedders/Emerson
16-3/4
Friedrich WSC
or 19-3/4
Emerson/Fedders
15
B
(pages 17~18)
C
(pages 19)
ITEM (inches)
Qty.
Plastic grille
26
3/4
x 16
1/2 
1
Vertical insulation strip
15
9/16
x 1
3/8 
x 1
3/8
1
Around Insulation Strips
67
1/8
x 1
3/8
25/32
1
59
27/32
x 1
3/8
x 1
3/8
1
Horizontal Insulation Strip
23
7/32
x 1
3/8
x 1
3/16
1
Support Block
1
3/4
x 1
3/8
x 4
5/16
2
Baffle
14 x 4
1/2
1/8
1
Shim
11
13/16
x 1 x 
3/4
2
Trim Frame
2
Washer Screw
4
Nuts(Plastic)
4
Grille Rear
1
CAUTION
Wall Sleeve Dimensions (inches)
Brand
Width
Height
Depth
White-Westinghouse
25-1/2
15-1/4
16, 17-1/2 
Frigidaire
or 22
Carrier (52F series)
General Electric
26
15-5/8
16-7/8
/Hotpoint
Whirlpool
25-7/8
16-1/2
17-1/8
or 23
Fedders/Emerson
27
16-3/4
16-3/4
Friedrich WSC
or 19-3/4
FRIEDRIC
H USC
25-7/8
15-17/32
16-23/32
Emerson/Fedders
26-3/4
15-3/4
15
Carrier (51S Series)
25-3/4
16-7/8
18-5/8