Installation requirements
STEP 1  The WSD SLEEVE should be positioned so that the 
DRAIN EXTENSION extends a minimum of 
9
16
" beyond 
the OUTSIDE WALL (See Figure 7).
STEP 2  The WSD SLEEVE must extend a minimum of  ⅞" beyond 
the  INSIDE WALL.
STEP 3  The WSD SLEEVE must be installed level side to side.
Sleeve installation
STEP 1
 
Please note that there will be an excess of two #12Ax2" 
screws that will not be used.
Figure 8
Back Unit Rest
Slope
Front Unit Rest
Level
Raised 
Ledge
STEP 4  The WSD SLEEVE must also be installed with a downward 
tilt toward the outside of the building.  If a level is placed 
so that it rests on the FRONT and BACK UNIT REST as 
shown in Figure 8, a properly installed unit provides a ½ 
bubble slope to the outside of the building.
STEP 2  Once the SLEEVE has been installed, check the LEVEL 
  .
d
e
ni
a
tn
ia
m
 s
i t
lit
 d
r
a
w
n
w
o
el
b
b
u
½
 e
h
e
r
u
e
ot
 n
ia
g
a
Apply shims, if required, to maintain the proper slope.
STEP 3  Caulk the perimeter of the entire opening on the inside and 
the outside between the SLEEVE and the WALL.
STEP 4
NOTICE
SLEEVE  projections  and  leveling  precautions 
must  be  observed  to  prevent    the  entry  of 
water into the room. 
After unpacking the WSD SLEEVE from the carton, remove 
the FRONT PANEL. Place the WSD SLEEVE in the wall 
opening following the instructions given in the INSTALLA-
TION  REQUIREMENTS.  Attach  the  SLEEVE  to  the 
INSIDE WALL by driving two #12A x 2" screws in each side 
of the SLEEVE (see Figure 7).  Shim at the top of the 
SLEEVE, midway between the sides. Drive one #12A x 2" 
screw in the top of the sleeve, close to the shim.  Install 
screws from inside the SLEEVE. If the wall opening is not 
framed with wood, use expansion anchor bolts or molly 
(toggle) bolts (not provided).  
The front panel removed in Step 1 above must  be remoun- 
ted back in place if masonry work is to be done and/or if the 
"WallMaster" CHASSIS is to be installed at a later date.