York CZH024 THRU 060 Manuale Utente

Pagina di 26
Subject to change without notice. Printed in U.S.A.
350154-YTG-C-0808
Copyright © 2008 by Johnson Controls, Inc. All rights reserved. 
Supersedes: 350154-YTG-B-0408
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed 
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
CZH06011
INDOOR COIL MODEL NO.
FC62D + MV20D
CONDENSER 
ENTERING AIR 
TEMPERATURE
ID CFM
1750
1850
1950
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
57.1 61.0 60.6 66.2 71.1 58.0 61.4 61.2 66.8 72.2 58.8 61.6 61.8 67.3 73.3 
S.C.
58.1 53.7 44.6 44.7 36.4 59.0 54.7 46.2 45.8 36.6 59.8 55.6 47.7 46.8 36.8 
K.W.
3.20 3.25 3.26 3.32 3.36 3.27 3.32 3.31 3.39 3.44 3.36 3.40 3.38 3.47 3.53 
75
T.C.
55.3 58.5 58.0 63.4 68.2 56.0 58.8 58.4 63.9 68.9 56.7 59.1 58.7 64.3 69.5 
S.C.
56.3 52.5 43.9 43.6 34.8 57.0 53.5 44.9 44.6 34.9 57.7 54.5 45.8 45.6 34.9 
K.W.
3.69 3.74 3.74 3.80 3.86 3.77 3.80 3.79 3.87 3.93 3.85 3.88 3.86 3.95 4.01 
85
T.C.
53.6 55.9 55.4 60.6 65.3 54.1 56.2 55.5 60.9 65.5 54.6 56.5 55.6 61.2 65.8 
S.C.
54.5 51.3 43.2 42.5 33.1 55.1 52.4 43.6 43.5 33.1 55.6 53.4 44.0 44.4 33.0 
K.W.
4.19 4.23 4.22 4.29 4.35 4.26 4.29 4.28 4.35 4.41 4.34 4.36 4.35 4.43 4.49 
95
T.C.
51.8 53.3 52.8 57.8 62.4 52.2 53.6 52.7 58.0 62.2 52.6 53.9 52.5 58.2 62.0 
S.C.
52.7 50.1 42.5 41.5 31.5 53.1 51.3 42.4 42.3 31.4 53.5 52.4 42.1 43.2 31.2 
K.W.
4.69 4.71 4.70 4.77 4.84 4.76 4.77 4.76 4.83 4.90 4.83 4.85 4.83 4.91 4.97 
105
T.C.
48.6 49.8 49.3 53.9 58.3 49.1 50.1 49.3 54.1 58.2 49.5 50.4 49.2 54.2 58.1 
S.C.
49.5 47.7 40.5 39.8 30.1 50.0 48.7 40.7 40.6 30.1 50.4 49.6 40.8 41.3 30.1 
K.W.
5.39 5.40 5.38 5.46 5.54 5.46 5.47 5.44 5.53 5.60 5.54 5.55 5.52 5.60 5.67 
115
T.C.
45.6 46.3 46.0 50.2 54.3 46.1 46.7 46.0 50.3 54.3 46.5 47.1 46.0 50.4 54.2 
S.C.
46.4 45.4 38.6 38.2 28.7 46.9 46.2 39.0 38.9 29.0 47.4 46.9 39.4 39.6 29.1 
K.W.
6.06 6.07 6.04 6.13 6.22 6.14 6.14 6.11 6.20 6.28 6.23 6.22 6.19 6.28 6.36 
125
T.C.
42.6 42.8 42.6 46.4 50.3 43.1 43.3 42.7 46.5 50.4 43.5 43.7 42.7 46.5 50.4 
S.C.
43.4 43.2 36.6 36.6 27.4 43.9 43.7 37.4 37.2 27.8 44.3 44.1 38.1 37.8 28.2 
K.W.
6.74 6.75 6.71 6.80 6.89 6.82 6.82 6.78 6.87 6.96 6.91 6.90 6.86 6.96 7.04 
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
AV/SV60D 
0.96 0.96 0.99 
F4FV060 
0.96 0.96 0.99 
MV20D 
FC/MC/PC60D 
0.96 0.96 0.99 
MV20D 
UC60D 
0.96 0.96 0.99 
MV20D 
FC/MC62D 
1.00 1.00 1.00 
Variable Speed 
Furnace
Coil
T.C.
S.C.
KW
PV8*C20
FC/PC60C 
0.95 0.95 1.00 
PV8*C20
FC/MC/PC60D 
0.95 0.95 1.00 
PV8*C20
UC60D 
0.95 0.95 1.00 
P(C,V)9*C20
FC/PC60C 
0.93 0.93 0.99 
P(C,V)9*C20
FC/MC/PC60D 
0.93 0.93 0.99 
P(C,V)9*C20
UC60D 
0.93 0.93 0.99 
P(C,V)9*D20
FC/MC/PC60D 
0.93 0.93 0.98 
P(C,V)9*D20
UC60D 
0.93 0.93 0.98 
PV8*C20
FC/MC62D 
0.98 0.98 1.01 
P(C,V)9*C20
FC/MC62D 
0.97 0.97 1.00 
P(C,V)9*D20
FC/MC62D 
0.97 0.97 0.99 
P(C,V)9*D20
HC60D 
0.94 0.94 0.98 
Y*9C*D20 
FC/MC62D 
0.97 0.94 1.02 
Y*(8,L)C*C20  FC/PC60C 
0.96 0.93 1.00 
Y*9C*C20 
FC/PC60C 
0.96 0.93 1.02 
Y*9C*D20 
HC60 
0.94 0.90 1.01 
Y*(8,L)C*C20  HD60 
0.97 0.93 1.00 
Y*9C*C20 
HD60 
0.97 0.94 1.03 
Y*9C*D20 
HD60 
0.96 0.92 1.02 
Y*(8,L)C*C20  UC60C 
0.94 0.89 1.00 
Y*9C*C20 
UC60C 
0.93 0.89 1.02 
Y*9C*D20 
UC60D 
0.94 0.89 1.01 
G*9V*D20 
FC/MC62D 
0.97 0.94 1.02 
G*9V*C20 
FC/PC60C 
0.96 0.93 1.02 
G*9V*D20 
HC60 
0.94 0.90 1.01 
G*9V*C20 
HD60 
0.97 0.94 1.03 
G*9V*D20 
HD60 
0.96 0.92 1.02 
G*9V*C20 
UC60C 
0.93 0.89 1.02 
G*9V*D20 
UC60D 
0.94 0.89 1.01 
Variable Speed 
Furnace
Coil
T.C.
S.C.
KW