Monessen Hearth DSSNVMB Manuale Utente

Pagina di 28
6                                                                                                                                                                                   
46D0550
46D0550                                                                                                                                                                                                      
7
PRODUCT SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/
2
" w.c. on Natural Gas 
systems operating at higher pressure.   
MILLIVOLT PRESSURE
Regulator Pressure Setting:        3.5" w.c.
Pilot Regulator:                           3.5" w.c.
Gas Inlet Pressure:                      Max. 10 1/2" w. c.             Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches.
 
Milli-Volt control has four (4) positions:
 
OFF 
All gas to the burner is shut off at the valve.
 
IGN 
Valve position to light/maintain a standing pilot.
 
ON 
Valve position to turn burners ON/OFF with remote switch/thermostat.
 
LOW/HI  - 
Variable position to control flame height (heat output). Both front and rear burners are in operation to 
provide realistic glow and yellow flame. 
 
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level.  The pilot can 
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote  activation.
 
 
 
  Gas Rate
 
Model Number  
Type 
Max. BTU/Hr    Min. BTU/Hr
 
DSSNVMB 
Milli-Volt 
28,000 
 
18,000
 
 
 
 
Gas Rate
 
Model Number  
Type 
Max. BTU/Hr   Min. BTU/Hr
 
DSSPVMB 
Milli-Volt 
28,000 
 
20,000
PROPANE / LPG
Note:  An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT PRESSURE
Regulator Pressure Setting:        10" w.c. 
Gas Inlet Pressure:                      Maximum 13" w.c.
                                                    Minimum 11" w.c.