INSTALLATION FOR VERTICAL TERMINA-
TION
1.  Determine the route your vertical venting will take. If 
ceiling joist, roof rafters or other framing will obstruct the 
venting system, consider an offset. Figure 18 to avoid 
cutting load bearing members. 
NOTE: Pay special attention to these installation instructions 
for required clearances (air space) to combustibles when 
passing  through  ceilings,  walls,  roofs,  enclosures,  attic 
rafters, etc. Do not pack air spaces with insulation. Also 
note maximum vertical rise of the venting system and any 
maximum  horizontal  offset  limitations.  Offsets  must  fall 
within the parameters shows in Figure 7 on page 12.
2.  Set stove in desired location. Drop a plumb line down 
from the ceiling to the position of the burner system exit 
flue. Mark the center point where the vent will penetrate 
the ceiling. Drill a small locating hole a this point. 
  Drop a plumb line from the inside of the roof to the locat-
ing hole in the ceiling. Mark the center point where the 
vent will penetrate the roof. Drill a small locating hole 
at this point. 
VENTING INSTALLATION 
Figure 17 - 
Horizontal Termination Configuration for Rigid Venting Using 
Three 90° Elbows with Termination at 90° with Stove 
Table 3 - Horizontal Venting with Three (3) Elbows
 
Vertical (V) + (V
1
Horizontal (H) + (H
1
 
 
Minimum 
Maximum
 
5' 
4'
 
6' 
6'
 
8' 
10'
 
20' 
12'
NOTE: Add 1/4" rise per 12" horizontal length of pipe.
HOT
H
H
1
V
1
V
ST1107
horiz term w 3 elbows
ST1107
FP1969
offset w/ wallstrap
Roof Flashing
Wall Strap
45° Elbows
Ceiling Firestop
FP1669
Figure 18 - 
Offset with Wall Strap and 45° Elbow