A.O. Smith FMD 40 Manuale Utente

Pagina di 56
8
These devices are available from some plumbing supply wholesalers 
and retailers, and detect and react to leakage in various ways:
•  Sensors mounted in the metal drain pan that trigger an alarm or 
turn off the incoming water to the water heater when leakage is 
detected.
•  Sensors mounted in the metal drain pan that turn off the water supply 
to the entire home when water is detected in the metal drain pan.
•  Water supply shut-off devices that activate based on the water 
pressure differential between the cold water and hot water pipes 
connected to the water heater.
•  Devices that will turn off the gas supply to a gas water heater while 
at the same time shutting off its water supply.  
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS 
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED 
(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable 
liquids (such as gasoline, solvents, propane [LP or butane, etc.] 
and other substances such as adhesives, etc.) emit fl ammable 
vapors which can be ignited by a gas water heater’s pilot light or 
main burner.  The resulting fl ashback and fi re can cause death or 
serious burns to anyone in the area,  as well as property damage. 
If installation in such areas is your only option, then the installation 
must be accomplished in a way that the pilot fl ame and main burner 
fl ame are elevated from the fl oor at least 18 inches (45.7 cm).  While 
this may reduce the chances of fl ammable vapors, from a fl oor spill 
being ignited, gasoline and other fl ammable substances should never 
be stored or used in the same room or area containing a gas water 
heater or other open fl ame or spark producing appliance. NOTE: 
Flammable vapors may be drawn by air currents from other areas 
of the structure to the appliance.
Also, the water heater must be located and/or protected so it is not 
subject to physical damage by a moving vehicle.
This water heater must not be installed directly on carpeting.  
Carpeting must be protected by metal or wood panel beneath the 
appliance extending beyond the full width and depth of the appliance 
by at least 3 inches (76.2 mm) in any direction, or if the appliance is 
installed in an alcove or closet, the entire fl oor must be covered by 
the panel.  Failure to heed this warning may result in a fi re hazard.
A gas water heater cannot operate properly without the correct 
amount of air for combustion.  Provide ventilation and combustion air 
by means of an air intake duct assembly as stated in “Water Heater 
Installation”.  Never obstruct the fl ow of ventilation air.  If you have any 
doubts or questions at all, call your gas supplier.  Failure to provide 
the proper amount of combustion air can result in a fi re or explosion 
and cause death, serious bodily injury, or property damage.
If this water heater will be used in beauty shops, barber shops, 
cleaning establishments, or self-service laundries with dry cleaning 
equipment, it is imperative that the water heater or water heaters 
be installed so that combustion and ventilation air be taken from 
outside these areas.  
Propellants of aerosol sprays and volatile compounds, (cleaners, 
chlorine based chemicals, refrigerants, etc.) in addition to being 
highly  fl ammable in many cases, will also change to corrosive 
hydrochloric acid when exposed to the combustion products of 
the water heater.  The results can be hazardous, and also cause 
product failure.
INSULATION BLANKETS
•  Do not obstruct water heater air 
intake with insulating blanket.
•  Gas and carbon monoxide detec tors 
are available.
•  Install water heater in accordance
with the instruction manual.
•  Install water heater in accordance
with the instruction manual and 
CAN/CSA B149.1-current edition 
( N a t u r a l   G a s   a n d   P r o p a n e 
Installation Code) and all local/
provincial codes.
•  To avoid injury, combustion and 
  ventilation air must be taken from 
 outdoors.
•  Do not place chemical vapor
  emitting products near water 
 heater.