5.2.3
Restarting the 
2230 Display
To restart the Rosemount 2230 choose one of the following options:
• choose the Restart option in the Service menu, see “Restart” on 
• press the Reset button inside the display cover, see Figure 5-2
• use the Restart command in TankMaster WinSetup (Right 
click>Restart)
The Restart option will connect the Rosemount 2230 Graphical Field Display 
to the Rosemount 2410 Tank Hub and perform start-up tests of software and 
hardware.
Figure 5-2. Reset button
NOTE!
Ensure that o-rings and seats are in good condition prior to mounting the 
cover in order to maintain the specified level of ingress protection. Cables 
must be properly attached to the cable glands.
Reset button
Cover