Honeywell DC6 Manuale Utente
![Honeywell](https://files.manualsbrain.com/attachments/04072ac208afe0f60402a9212acd23d57421a7fb/common/fit/150/50/3e168605118cbbd2e280a10aaeca155d86bc5b4c616b0334def9ca6d226c/brand_logo.png)
15
Inserting the check valve assmbly into the pump in the wrong directiom, or having the check seat
upside down, will prevent proper seals at the o-rings, decrease pump performance, and can cause
damage to the diaphragm.
upside down, will prevent proper seals at the o-rings, decrease pump performance, and can cause
damage to the diaphragm.
12. Carefully make sure that the check assemblies are in proper position, and tighten the four tie-bar
bolts, using a star pattern, to a torque of 6 Ft-lbs (8 N-m).
13. Retighten any unions, flanges, or other process connections that may have been loosened previously.
Figure 12, DC5 and 6 check valves, metal construction