163   VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
Starting HSC Execution 
Initialize the HSC. Refer to “Starting the HSC” on page 165 for information about how to 
start execution of the HSC. 
Note: The subsystem name specified with the LIBSUBSYS parameter in the SYSPROF 
must match the jobname in the startup SLKJCL file or it must be specified with the SSYS 
parameter in the /PARM statement. Refer to “SSYS” on page 158 for more information. 
When phases of HSC initialization are completed, messages are displayed indicating 
completion of the initialization phases. Messages inform you when HSC base service level 
and when HSC full service level initialization is completed. 
If SMF options for the HSC were not specified by a SET PERFlog command in the system 
profile, the HSC issues a message that SMF record subtypes 1 through 6 are being 
recorded. 
If you did not specify GTF Eid and Fid parameters on the /PARM statement in the HSC 
startup SLKJCL, HSC issues a message indicating that default Eid and Fid values are 
being used. 
HSC may be started prior to hardware arrival to ensure that it has been installed properly. 
The HSC subsystem comes up with the LMU stations offline. HSC operator commands 
may be entered, but any functions requiring interaction with the ACS hardware result in 
error messages. 
Modifying LSMs Online 
When the CDS is initialized, the status of all LSMs defined in the LIBGEN is OFFLINE. 
You must issue the HSC MODify ONline command to bring all of your LSMs online. 
For subsequent executions of the HSC, the last recorded status of the LSMs is obtained 
from the control data set. 
Specifying CAP Preferences 
When the CDS is initialized, all CAP preferences are zero (never selected). You must issue 
the CAPPREF command and control statement to establish a preference value for a CAP. 
The HSC selects CAPs based on the preference value. Refer to ‘‘CAP Preference 
(CAPPref) Command and Control Statement’’ in the HSC Operator’s Guide for more 
information. 
Configuration Mismatches 
During HSC initialization, the HSC remains active if LSM or panel type configuration 
mismatches occur between the CDS and LMU. Specifically, these mismatches include: 
• different numbers of LSMs 
• different or unknown types of LSMs 
• different or unknown panel types in an LSM.