PW SR (Pulse width trigger SYNC-RESET)
( 4 ) 
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
1 Pulse Width Trigger SYNC-RESET Picture Output Timing
(4. 1) 
Exposure completion
0 to 1H
Negative polarity mode
Positive polarity mode
FVAL
About 1 
µs
About 7 
µs
Exposure period*
2
Trigger*
1
(Internal VD)*
3
*
4
RGB data
(video interval image)
LVAL,
DVAL 
28H 
(Partial scanning OFF)
25H 
(Partial scanning 40fps)
27H 
(Partial scanning 42fps)
33H 
(Partial scanning 50fps)
39H 
(Partial scanning 60fps)
43H 
(Partial scanning 70fps)
46H 
(Partial scanning 80fps)
48H 
(Partial scanning 90fps)
*1: External input signal
*2:  Exposure time = Trigger pulse width + 6 µs  
 
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3:  VD is generated after 0 to 1H following the completion of the exposure period and the video is synchronized to 
this and output.
*4:  When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there 
will be an effect on the video.