DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-847
EXT-DEV ADMIN? Y (External Device Alarm) 
9
Table 9-320.
TEST #120 External Device Alarm Test 
Error 
Code
Test 
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1035
ABORT
The EPN containing this equipment is not available.
Resolve all EPN problems with this cabinet.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. (Maintenance Board) If the test continues to ABORT with Error Code 2000, 
check for system powering problems with the A carrier. Resolve all 
AC-POWER and CARR-POW alarms in a multi-carrier cabinet or 
DC-POWER alarms in a single-carrier cabinet. Then, repeat the test.
3. (Maintenance Board) If the test continues to ABORT with a 2000 Error 
Code, resolve all maintenance circuit pack errors. Then, repeat the test.
2029
2100
2319 
2320 
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY
FAIL
The External Device Alarm has been activated by the external device.
1. Clear the major alarm on the external device, and rerun the test.
2. If the test still fails, then disconnect the External Device Alarm Leads from 
the Maintenance circuit pack and rerun the test.
3. If the test still fails, then there is a problem with the analog external device 
alarm port or the Maintenance circuit pack that is reporting the alarm. This 
circuit pack should be replaced. There are failures that can occur on the 
Maintenance circuit pack that 
will not be detected by their respective 
maintenance, but which will cause many environment tests to fail. If many 
environment tests are failing, the suspect circuit pack should be replaced 
and the test rerun.
PASS
If there is a problem with the external device, but the administered analog line 
external device alarm, or the administered Maintenance circuit pack connected 
to the device reports no alarm, then the External Device may not be properly 
reporting the problems or the External Device may not be properly connected 
to the External Device Alarm Leads.
Continued on next page