Lucent Technologies Release 7 Manuale Utente
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1493
STBY-SPE (Standby SPE Maintenance)
9
STBY-SPE (Standby SPE Maintenance)
The general principles of SPE duplication, including the following topics, are
discussed in Chapter 1:
discussed in Chapter 1:
■
Standby Maintenance Architecture
■
■
■
■
■
Standby Initialization
Troubleshooting a duplicated SPE, and replacing SPE components, are
discussed in Chapter 5. The SPE-Down or SPE-Locked interface is discussed in
Chapter 4.
discussed in Chapter 5. The SPE-Down or SPE-Locked interface is discussed in
Chapter 4.
Maintenance of the standby SPE is organized around the STBY-SPE
maintenance object. It relies on documentation of the other SPE maintenance
objects:
maintenance object. It relies on documentation of the other SPE maintenance
objects:
Once a general SPE problem has been isolated to the level of one of these
individual packs, the service documentation for that MO should be consulted. It
is the responsibility of standby SPE maintenance described here to keep the
standby SPE fully available for an interchange.
individual packs, the service documentation for that MO should be consulted. It
is the responsibility of standby SPE maintenance described here to keep the
standby SPE fully available for an interchange.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
STBY-SPE
MAJOR
test spe-standby l
Standby SPE Maintenance
STBY-SPE
MINOR
test spe-standby l
Standby SPE Maintenance
STBY-SPE
WARNING
test spe-standby l
Standby SPE Maintenance
PROCR
SYSAM
MEM-BD
SW-CTL
H-ADAPTR
TAPE
DISK
DUPINT
DUP-CHL