LED Interpretation 
7-7
Duplication Interface Circuit Pack LEDs 
7
Duplication Interface Circuit Pack 
LEDs
In systems with duplicated SPEs, (High Reliability and Critical Reliability), there 
are two Duplication Interface UN330B circuit packs. One is located in carrier A 
and one in carrier B of the PPN. Each circuit pack has four LEDs. The top three 
have the traditional function of indicating the status of the pack.
The LED located at the bottom of the faceplate directly beneath the SPE Select 
switch is labeled OVERRIDE. Under normal operating conditions, the SPE Select 
switch is in the AUTO (center) position, and the OVERRIDE LED remains unlit. 
This means that the system controls which SPE is active. System selection of the 
active SPE can be manually overridden by moving the SPE Select switches from 
the AUTO position to either the “A” position or the “B” position on both 
Duplication Interface circuit packs. At this time, the red OVERRIDE LEDs on both 
Duplication Interface circuit packs will light steadily to indicate that one SPE is 
locked Active and the system is not duplicated. If both SPE Select switches are 
not in the same position, the system software retains control of Active SPE 
selection, and the OVERRIDE LED remains unlit. When control of the SPE 
selection is returned to the system by returning the SPE Select switches on both 
Duplication Interface circuit packs to the AUTO position, the OVERRIDE LED will 
go dark. Forced SPE selection should be undertaken only after consulting the 
appropriate sections in 
Chapter 9, ‘‘Maintenance Object Repair Procedures’’
.