Install Management Terminal and Activate System 
Page 3-29
Reboot High Reliability System 
3
Reboot High Reliability System
1. Enter reset system 4.
2. When the 
login:
 prompt appears, login as craft.
3. About eight minutes after booting and at the 
Command:
 prompt, enter the 
status spe
 
command.
4. Verify that 
handshake, shadowing,
 and 
refreshed
 are all shown to 
be either 
yes
 or 
on
.
Enable Duplication and Boot Critical Reliability
System (Release 6r)
1. Enter change system-parameters duplication.
2. Make sure duplication of both SPE and PNC are enabled on the screen 
that follows the command. Confirm that a 
y
 is contained in both fields.
3. Enter save translation.
4. Enter reset system 4 to reboot the system.
5. When 
login:
 appears on the screen, login as craft.
6. About eight minutes after booting the system and at the 
Command:
 
prompt, enter the status spe command.
7. Verify that 
handshake, shadowing,
 and 
refreshed
 are all shown to 
be either 
yes
 or 
on
.
Administer Attendant Console
1. Enter display system-parameters country-options
 
and press 
Enter
 to 
verify the system’s companding mode for its local stations is set to the 
desired value (usually, A-Law for Europe and mu-Law for North America 
and Japan).
2. If necessary, enter change terminal-parameters 603/302B1
 
and press 
Enter
 to change the default system-level parameters and audio levels for 
these terminals.
NOTE:
For information about changing the default parameters and audio 
levels, refer to 
DEFINITY Application Notes
 available through the 
International Technical Assistance Center (ITAC).
3. Administer other forms listed under Attendant Console in 
DEFINITY 
Enterprise Communications Server Release 6 Administration and Feature 
Description
.