DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-14
Adjunct Power Connections 
5
Adjunct Power Connections
Figure 5-9
 shows 3 typical connection locations for adjunct power. Adjunct 
power for station equipment may be supplied from the equipment room, satellite 
location, or the work location.
Figure 5-9.
Example Adjunct Power Connections
For 
Figure 5-9
, the following example is used:
a. If 25 telephones connect to the system and all 25 telephones need 
adjunct power, install the adjunct power supply in the equipment room.
b. If only 10 of the telephones need adjunct power, install the adjunct power 
supply at the satellite location.
c. If only 1 telephone needs adjunct power, install the adjunct power supply 
at the work location.
Figure Notes
1. Typical Display Telephone
2. Adjunct Power Supply (Such as 1151A or 
1151A2)
3. 400B2 Adapter
4. Information Outlet 
5. 4-Pair D-Inside Wire (DIW) Cable
6. Satellite Site or Adapter Location
7. 25-Pair D-Inside Wire (DIW) Cable
8. Station Side of Main Distribution Frame 
9. 100P6A Patch Cord or Jumpers
10. System Side of MDF 
11. 25-Pair Cable to System Cabinet 
Analog Line Circuit Pack
12. Equipment Room
13. Satellite Location
14. Work Location
15. Power From Bulk Power Source (Such 
as 1145B)
4
adjunct_1 PDH 062696