Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-105
Add External Modem to TN1648B 
5
10. Connect the cable to the front of the TN1648B circuit pack as shown in 
Figure 5-52
.
NOTE:
Dress the cable straight down the front of the circuit pack. Do not 
allow the cable to cross in front of another circuit pack.
Figure 5-52.
Connect the Cable to the Circuit Pack
11. Close the front door.
12. Discard the pass-thru tool.
Test the Installation
1. Login to the management terminal.
2. Administer the system by referring to the 
Installation and Test for Adjuncts 
and Peripherals, 555-230-125
.
3. Enter list configuration all to determine if the new circuit pack appears in 
the correct slot and that there are no circuit pack conflicts.
prda0007 RPY 021698