Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-112
Add ISDN — PRI 
5
Enter Added Translations
1. Administer the forms listed under “Integrated Services Digital Network — 
Primary Rate Interface” in 
DEFINITY Enterprise Communications Server 
Release 6 Administration and Feature Description
.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance R6vs/si
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS 
Database Administrator at the Technical Service Center (TSC). Verify that INADS 
can dial into the system and that the system can dial out to INADS. 
As part of the system registration process, the INADS Database Administrator 
enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has purchased a 
services contract, the system cannot report any alarm to the TSC 
automatically, causing the TSC to be unable to fulfill the services contract.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation memory 
card or the tape.
3. If the system contains a TN750 Announcement circuit pack, enter list 
configuration software-version and press 
Enter
. If Page 2 of this form 
shows that recorded announcements were saved, these announcements 
can be restored using restore announcements and press 
Enter
.
4. Update backup tape, if necessary.