Option Switch Settings 
Page B-2
External Modem Option Settings 
B
External Modem Option Settings
The COMSPHERE 3700, 3800, and 3900 series (recommended) external 
modems may require option switch settings. Refer to the documentation that 
accompanies each modem to set the options. 
NOTE:
A locally obtained, type-approved external modem may be used. Contact 
your Lucent Technologies representative for more information.
The Release 6 systems operate with the COMSPHERE modems set to the factory 
default settings. The modem settings and descriptions are listed in 
Table B-1
.
Table B-1.
Modem Fields 
Modem 
Connection
 Description
Modem Name
This field is 20 characters long and permits alphanumeric characters to 
provide a unique qualifier for a given modem (such as INTEL).
RTS/CTS 
Enabled
Informs the modem that communication with the data source UART is 
driven with RTS/CTS flow control. The field name has a default of \Q3 in a 
field 6 characters long. This field is not case sensitive. Default is upper 
case.
Asynchronous
 Data Mode
Configures modem as an asynchronous communications device. The 
field name has a default value of &M0&Q0 in a field 8 characters long. 
This field is not case sensitive. Default is upper case.
DTE 
Auto-Data 
Speed
Adjusts the speed of the data source (DTE) UART to the outgoing 
(modem-to-modem) data rate. At maximum, this speed is 9600 baud. It is 
not desirable to have the serial data fill the modem buffer faster than the 
outgoing data rate, since data compression is disabled. The field name 
has a blank default value in a field of 6 characters. The Lucent products 
use the command S90=1 to enable this functionality while the Intel 
product uses the command \J1 to enable similar functionality. This field is 
not case sensitive. Default is upper case.
Disable Data 
Compression
Turns off the default data compression algorithms in use by most 
modems. The field has a blank field of 6 characters as default. The AT 
commands that control this are supported by similar commands; 
however, these commands do not operate in the same manner. The Intel 
modems require “H0%C0” to disable V.42bis & MNP Class 5 data 
compression algorithms. The Paradyne products only use %C0 to disable 
both algorithms. This field is not case sensitive. Default is upper case.
Continued on next page