JVC 237VP Manuale Utente

Pagina di 108
90 
Allowed users  admin, operator, user 
 
Getting Firmware Revisions 
Format  /api/param?system.software.revision 
Example of Response  system.software.revision=1.00&200 OK 
Interpretation  Acquire revisions of the firmware. 
Allowed users  admin, operator, user 
 
Getting Software ID 
Format  /api/param?system.software.programid 
Response  Return software ID.  
Response examples  
system.software.programid=SPL0123&200 OK 
Interpretation  Acquire the software ID.  
Allowed user  admin 
 
 
28. JVC API for Others 
These are APIs of features not found on the WEB setting page. 
 
Getting Alarm Input Status  (VN-H57/157/257) 
Format  /api/param?peripheral.input_pin.pin(Number).status 
Example of Response  peripheral.input_pin.pin(1).status=make&200 OK 
Interpretation  Acquire the current alarm input status. Specify 1 or 2 to Number. Either make or break will be 
returned. 
Allowed users  admin, operator, user 
 
Getting Mode of FTP Server  
Format  /api/param?application.ftp.mode 
Example of Response  application.ftp.mode=active&200 OK 
Interpretation  Acquire the mode of FTP server that is used by alarm action. Either active or passive is returned. 
   active mode: Standard mode of FTP server. Also called PORT mode. TCP connection for data is established 
from 20 port of FTP server to 10020 port of the camera. 
   passive mode: TCP connection for data is established from the camera to FTP server. Port number depends on 
FTP server. 
Allowed users  admin, operator, user