Spa Model
GFCI Required Wires Required
Portable Spas
All 230V spas (except 
6205 control boxes re-
quiring high amperage 
- see below)
One 32 amp RCD or 
two 16 amp RCDs
Three #10 AWG cop-
per wires
Spas with the 6300 
control box (when high 
amperage is selected on 
circuit board)
SEE CONFIGURATION 
INSTRUCTIONS ON 
NEXT PAGE.
One 32 amp RCD or 
two 16 amp RCDs
Three #10 AWG cop-
per wires
Ul
timate Fi
tness Spas
F2400 spas with one 5.5 
kW heater
One 32 amp RCD or 
two 16 amp RCDs
Three #10 AWG cop-
per wires
FP2500 spa with 
one 5.5 kW heater and 
one 3 kW heater
Service 1: One 32 
amp RCD or two 16 
amp RCDs
Service 1: Three #10 
AWG copper wires
Service 2: One 32 
amp RCD
Service 2: Three #10 
AWG copper wires
FP4700 spa
Service 1 (swim 
side): One 32 amp 
RCD
Service 1: Three #10 
AWG copper wires
Service 2 (swim 
side): One 32 amp 
RCD
Service 2: Three #10 
AWG copper wires
Service 3 (spa side): 
One 32 amp RCD
Service 3: Three #10 
AWG copper wires
In-Gr
ound Spas
Designer in-ground spas 
with one 3 kW heater
One 32 amp RCD or 
two 16 amp RCDs
Three #10 AWG cop-
per wires
Designer in-ground spa 
with one 3 kW heater 
and one 5.5 kW heater
Service 1: One 32 
amp RCD or two 16 
amp RCDs
Service 1: Three #10 
AWG copper wires
Service 2: One 32 
amp RCD
Service 2: Three #10 
AWG copper wires