introduction
pressure Switch - ON/OFF Switch - In 
the ON position, the compressor shuts 
off automatically when tank pressure 
reaches the maximum preset pressure. 
In the OFF position, the compressor will 
not operate. This switch should be in 
the OFF position when connecting or 
disconnecting the power cord from the 
electrical outlet or when changing air 
tools.
regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet.
aSMe Safety valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum.
exhaust tube - This tube carries 
compressed air from the pump to the 
check valve. This tube becomes very hot 
during use. To avoid the risk of severe 
burns, never touch the exhaust tube.
check valve  - A one-way valve 
that allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.
handle - Designed to move the 
compressor.
air outlet - A quick connect coupler 
designed to work in combination with 
a quick connect plug to quickly and 
easily join a pneumatic tool to an air 
hose.
pressure Gauges - These gauges will 
show air pressure in the compressor 
tank and at the compressor outlet.
outlet pressure Gauge - Will show 
air pressure at the outlet in pounds per 
square inch (psi). Make sure this gauge 
reads ZERO (by adjusting regulator 
knob fully counterclockwise) before 
changing air tools or disconnecting air 
hose from outlet.
tank pressure Gauge - Will show air 
pressure in tank while the compressor 
is running, indicating compressor 
is building pressure properly. This 
gauge will show maximum pressure 
of compressor when it shuts off 
automatically at the pressure switch.
Drain valve - This valve is located 
underneath the tank. Use this valve to 
drain moisture from the tank daily to 
reduce the risk of corrosion.
 
Drain liquid from  
  tank daily.
Reduce tank pressure below 10 psi, 
then drain moisture from tank daily to 
avoid tank corrosion. Drain moisture 
from tank by opening the drain valve 
located underneath the tank.
installation
location
It is extremely important to install the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.
 
Do not locate the 
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor
household use only. Store indoors.
electrical inStallation
 1.  Check and tighten all bolts, fittings, 
etc., before operating compressor.
 2.  Operate compressor in a ventilated 
area so that compressor may be 
properly cooled.
 3.  Compressor should be located 
where it can be directly plugged 
into an outlet, but if this is not 
possible, an extension cord may be 
used. It should be selected using the 
extension cord chart on page 5 as a 
guide.
 4.  To avoid loss of power and 
overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.
Figure 3
ASME Safety 
Valve
Pressure Switch
Tank Pressure 
Gauge
Outlet Pressure Gauge
Regulator
Air Outlet
4
Operating Instructions
www.chpower.com