ADIC 601356 Manuale Utente

Pagina di 192
Command Reference
601356 Rev A
Command Reference
2-3
Commands
volserv
Starts or ends VolServ and activates the system log display.
Parameters
volserv -s
volserv -t | -q
volserv [-y]
Parameters
Parameters
Description
-s
Starts VolServ in the single user mode. Only 
commands run with 
vswin
 are run. Client 
interface commands are refused.
-t
Terminates the VolServ operations. VolServ 
terminates gracefully. Outstanding commands are 
cancelled and any commands awaiting status are 
allowed to complete (within a certain time period).
The termination of VolServ prompts the user to 
continue the software termination. 
• If  the  -y option is specified, the prompt is 
automatically answered as “yes” and the 
software is terminated automatically.
NOTE: If a VolServ request is submitted to the 
system duringVolServ system termination, 
VolServ issues a message which states that the 
system is unavailable. 
-q
Quits the VolServ operations. The user will be 
prompted to verify if the software should really be 
shutdown if the -y option is not specified..
-y
Automatically answers the command prompt with 
a “yes.”