Lexmark 4039-1XX Manuale Utente

Pagina di 188
Diagnostic Information
31
4039-1XX
If the problem is still present, replace one at a time the:
1. ROM SIMM
2. System board
Vertical Void or Streak
Do a developed image test to determine if the defect is occurring 
before or after the transfer process.
If you see the defect on the photoconductor, check the operation of 
the printhead shutter and clean the printhead window with a lint-free 
cloth folded over a cotton swab; do not use a bare swab and do not 
use any cleaning fluids or water on the printhead window. Inspect 
the HVPS contacts.
If the image on the photoconductor is good, inspect the fuser rolls 
and transfer roll. Make sure the left transfer roll bearing is contacting 
the contact from the HVPS. Make sure the HVPS contacts are clean 
and spring back when pressed.