Test-Um NT955 Manuale Utente

Pagina di 97
24
Test-Um NT955 Series
Validator-NT Main Unit
When powered on, the Validator-NT reports the charging status at the top 
of the screen under the battery icon.  A green full battery icon indicates 
the battery is fully charged. As the battery discharges, the percentage of 
remaining charge is displayed in 10% steps. The battery icon changes 
from green to amber when the battery reaches approximately 30% of its 
charge capacity.  
When the battery is Low, the battery icon will change to red and 
begin to flash.  An audible warning tone will sound when the battery 
reaches approximately 10% of its charge capacity to notify the user 
that in approximately three minutes, the Validator-NT will power down 
automatically and save the current job. 
Note: The battery must be fully charged the first time it is used to re-
port charging status. After one full charge, the batteries in the main unit 
and the remote unit are interchangeable.
If the battery is replaced, it is necessary to start a new charge cycle by 
either disconnecting the AC
 
adapter momentarily or pressing the Reset 
Charge (RST CHRG) soft key (F1) on the Properties/Battery Info screen. 
 
In addition to the charging status, additional information that is useful to 
monitor the loss of capacity in the battery over time is displayed on the 
Battery Properties screen.
Charging will continue when the Validator-NT is powered off but there is 
no visual indication.  The Validator-NT has various timeout conditions to 
conserve battery life.  The specific timeout values are adjustable in the 
Setup, Shutdown Timeouts screen.
Validator
TM
 Battery and Power Management
Validator
TM
 Battery and Power Management