Agilent Technologies DC110 Manuale Utente

Pagina di 66
 
 
User Manual: Family of 8-bit Digitizers 
 
Page 6 of 66 
DC271-FAMILY  
DC135/DC140/DC211/DC211A/DC241/DC241A/ 
                                                DC271/DC271A/ DC271AR/DP214/DP235/DP240 
1.4. 
Disclaimer and Safety 
The DP Series PCI Digitizer cards have been designed to operate in a standard PCI slot found inside most personal 
computers. The model DC Series CompactPCI/PXI Digitizers have been designed to operate inside a 
CompactPCI/PXI crate. The crate provides the modules with all needed power. Agilent Technologies does not 
recommend operation of the DC Series modules outside of a CompactPCI/PXI crate.  
CAUTION:
  
Do not exceed the maximum input voltage rating! The maximum input voltage for 50 
Ω
  input 
impedance is 
±
5 V. The maximum input for 1 M
Ω
  input impedance is 
±
100 V (dc + ac) except 
for the DC2x1A/AR models where it is 
±
300 V (dc + ac) . 
1.5. 
Warning Regarding Medical Use 
The Digitizer cards are not designed with components and testing procedures that would ensure a level of reliability 
suitable for use in treatment and diagnosis of humans. Applications of these cards involving medical or clinical 
treatment can create a potential for accidental injury caused by product failure, or by errors on the part of the user. 
These cards are not intended to be a substitute for any form of established process or equipment used to monitor or 
safeguard human health and safety in medical treatment. 
WARNING:
  
The modules discussed in this manual have not been designed for making direct measurements 
on the human body. Users who connect an Acqiris module to a human body do so at their own 
risk. 
1.6. 
Packaging and Handling 
Your Digitizer is shipped with the following components: 
•  A small 3.5” compact disc in an Acqiris paper CD envelope that includes  
o
 
10 product user manuals in electronic form (Signal Analyzers, Streamer Analyzers, Family of 8-bit 
Digitizers, Family of 10-bit Digitizers, Family of 12-bit Digitizers, Family of Averagers, Family of 
Analyzers, Family of Time Counters, CC10X Family of CompactPCI Crates and CC121 
CompactPCI Crate), 
o
 
1 Programmer’s Guide and 1 Programmer’s Reference Manual, 
o
 
device drivers with sample software for different operating systems, environments and languages,  
o
 
the AcqirisAnalyzers application, a demonstration program for the AC/SC Analyzer products, 
o
 
the AcqirisLive application, a demonstration program for our digitizer and averager products, 
o
 
the DemoSSR application, a demonstration program for the Acqiris AP235/AP240 Analyzers, 
o
 
the DemoAPX01 application, a demonstration program for the Acqiris AP101/AP201 Analyzers, 
o
 
the DemoTC application, a demonstration program for the Acqiris TC840/TC890 Time Counters, 
o
 
product data sheets,  
o
 
full installation procedures for use with Microsoft Windows, National Instruments LabVIEW RT, 
Wind River VxWorks, IVI-COM/C, and Linux software.  
•  A declaration of conformity 
•  Optional documentation such as a model-dependent document giving Specifications & Characteristics, a 
Calibration Certificate, or a Performance Verification 
After carefully unpacking all items, inspect each to ensure there are no signs of visible damage. Also check that all 
the components received match those listed on the enclosed packing list. Agilent Technologies cannot accept 
responsibility for missing items unless we are notified promptly of any discrepancies. If any items are found to be 
missing or are received in a damaged condition please contact the Agilent service center or your local supplier 
immediately. Retain the box and packing materials for possible inspection and/or reshipment.