Toshiba B-EX Manuale Utente

Pagina di 95
 
41
[Product] Group 
[Printer Serial No.]: 
The serial number specific to the printer is displayed. 
This setting cannot be changed. 
 
[SHELL]: 
The status of the SHELL function is displayed. 
This setting cannot be changed. 
 
[Sensor] Group 
[Reflective Sensor Threshold Select]: 
Select how to set the threshold for the reflective sensor. 
Default Command 
Set 
Options 
Manual Set, Command Set 
 
[Reflective Sensor Threshold]: 
Set a fine adjustment value for threshold to the reflective sensor output in units of 0.1 V. 
Default 1.0 
Range 
0.1 to 4.0 V 
 
[Transmissive Sensor Threshold Select]: 
Select how to set the threshold for the transmissive sensor. 
Default Command 
Set 
Options 
Manual Set, Command Set 
 
[Transmissive Sensor Threshold]: 
Set a fine adjustment value for threshold to the transmissive sensor output in units of 0.1 V. 
Default 1.4 
Range 
0.1 to 4.0 V 
 
[Ribbon Adjustment] Group 
[Drive Voltage (Take-up)]: 
Fine adjust the ribbon take-up motor voltage (torque). 
The fine adjustment value set by the Ribbon Motor Drive Voltage Fine Adjust command [RM] is 
displayed in the left box. 
When the parameter is not retrieved, the value in the left box becomes zero (0). 
Default 0 
Range 
-15 to +10 
 
[Drive Voltage (Feed)]: 
Fine adjust the ribbon feed motor voltage (torque). 
The fine adjustment value set by the Ribbon Motor Drive Voltage Fine Adjust command [RM] is 
displayed in the left box. 
When the parameter is not retrieved, the value in the left box becomes zero (0). 
Default 0 
Range 
-15 to +10 
 
[RTC] Group 
[Date Time]: 
The current date and time programmed for the RTC module are displayed. 
This setting cannot be changed. 
 
[Battery Check]: 
Select whether to enable or disable the battery check function. 
Default Disable 
Options Disable, 
Enable 
 
[Renewal]: 
Select the timing when the date and time are updated during printing. 
Default Batch 
Options Batch, 
Page