IBM SG24-5131-00 Manuale Utente

Pagina di 240
Cluster Management and Administration 
165
Lazy Update has some limitations, which you need to consider when you rely 
on Lazy Update in general:
  • If the first disk in a sharedvg has been replaced, the 
importvg
 command 
will fail as Lazy Update expects to be able to match the hdisk number for 
the first disk to a valid PVID in the ODM.
  • Multi-LUN support on the SCSI RAID cabinets can be very confusing to 
Lazy Update as each LUN appears as a new hdisk known to only one 
node in the cluster (remember that Lazy Update works on LVM 
constructs).
8.4.3  C-SPOC
The Cluster Single Point of Control (C-SPOC) utility lets system 
administrators perform administrative tasks on all cluster nodes from any 
node in the cluster. These tasks are based on commonly performed AIX 
system administration commands that let you:
  • Maintain user and group accounts (see 8.8, “User Management” on page 
  • Maintain shared Logical Volume Manager (LVM) components.
  • Control HACMP services on a cluster-wide basis (see Chapter 8.2, 
Without C-SPOC functionality, the system administrator must spend time 
executing administrative tasks individually on each cluster node. Using the 
C-SPOC utility, a command executed on one node is also executed on other 
cluster nodes. Thus C-SPOC minimizes administrative overhead and reduces 
the possibility of inconsistent node states. For example, to add a user, you 
usually must perform this task on each cluster node. Using C-SPOC, 
however, you issue a C-SPOC command once on a single node, and the user 
is added to all specified cluster nodes.
C-SPOC also makes managing logical volume components and controlling 
cluster services more efficient. You can use the C-SPOC utility to start or stop 
cluster services on nodes from a single node.
C-SPOC provides this functionality through its own set of cluster 
administration commands, accessible through SMIT menus and screens. To 
use C-SPOC, select the Cluster System Management option from the 
HACMP for AIX menu. See the 
HACMP for AIX, Version 4.3: Administration 
Guide, SC23-4279 for detailed information on using C-SPOC SMIT options.
With C-SPOC, you can perform the following tasks: