3M 40800 Manuale Utente

Pagina di 122
26 
2011 June
700a-NA 
12-OPERATION (continued)
PROBLEM
CAUSE
CORRECTION
 (continued on next page)
  PROBLEM
 CAUSE
 CORRECTION
  When pressing the ON button
  the machine does not start
  The magnetothermic protection
  opens the main switch
  Drive belts do not convey 
  boxes
  Drive belts do not turn
  The lockable emergency stop
  button is pressed
  Motor under stress
  Thermal cut-out not at correct
  amperage setting
  Narrow boxes
  Worn drive belts
  Taping head applying spring
  holder missing
  Taping head applying spring
  set too high
  Worn or missing friction rings
  Drive belt tension too low
  Electrical disconnect
   Motor not turning
  Release the emergency stop
  button
  Check the electrical system
  Check that the drive belts are
  not blocked
  Set the correct amperage
  Check machine specifi cations
  Boxes are narrower than
  recommended, causing
  slippage and premature belt
  wear
  Replace drive belts
  Adjust the box height adjust-
  ment with the crank
  Reduce spring pressure
  Replace friction rings
  Adjust belt tension
  Check power and electrical
  plug
  Evaluate problem and correct
12.9  Troubleshooting Guide