Toshiba 3511 Manuale Utente
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
November 2003 © TOSHIBA TEC
3 - 7
e-STUDIO3511/4511 ADJUSTMENT
[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [FAX] button,
immediately after starting the Adjustment Mode (05), single-sided test copying can be performed
(normal copy mode).
0
1
5
POWER
ENTER
INTERRUPT
FAX
Digital keys
START
: Key in codes.
<Operation keys>
<Display>
Varies with the code “XXX” keyed in.
Current adjustment value
Adjustment value newly keyed in.
(If no entering, YYY is displayed.)
(If no entering, YYY is displayed.)
Power OFF/ON : Exit the Adjustment Mode.
Test copy
Digital keys
START
: Key in adjustment
values.
values.
Value ZZZ is stored
replacing values YYY.
replacing values YYY.
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
or
( CLEAR Use to make corrections)
100%
A
A3
TEST MODE
100%
A
A3
TEST MODE
100%
A
A3
Wait Warming Up
100%
A
A3
COPYING
Code No.
100%
YYY
ZZZ
XXX
A3
TEST MODE