Connection for power 
RJ-45 Connection 
7.  Pull retractable safety cable 
from bottom of camera and 
insert into hook, inside upper 
housing. 
(figure 7a) 
  
1.  Remove junction box cover with supplied hex tool to view inner connection block. 
(figure 1a) 
Inner connection block exposes connections for power, video, alarm input/output as well 
as dip switches for selecting camera ID, protocol, baud rate and termination. 
(figure 1b) 
See 
manual for proper settings. 
2.  Attach wall mount to wall with supplied anchor bolts and make connections.  
Inner Box connections 
*Note for RS-485 Connection: 
GVI uses solid colored wire to represent posi-
tive (+) and striped wire for negative(-) polar-
ity. Regardless of the wire color you choose 
make sure polarity matches on both ends of 
the connection 
Cable connection for dome. Connect 
cable from mount into upper housing 
Inside view of upper housing 
3.  Remove camera mechanism from upper housing. 
(figure 3a) 
  
4.  Use Teflon tape (included) to wrap around pipe fitting. 
(figure 4a) 
  
5.  Attach safety cable to neck of mount. 
(figure 5a) 
  
6.  Attach other end of safety cable to housing 
(figure 6a) 
 and now screw in upper 
housing to mount pole, bring in cable from pole mount and attach. 
(figure 6b) 
  
 
Safety cable to mount 
Teflon tape for tight connection 
Safety cable to housing 
1a 
1b 
2a 
2b 
4a 
5a 
6a 
3a 
Retractable safety cable  
6b 
7a 
 
 
SCC/SNC-C7478 Installation Guide
 
  
 
 
SAMSUNG | GVI Security, Inc
.
 
Phone: 972-245-7353 • Toll Free: 888-595-2288 • Fax: 972-245-7333 
www.samsung-security.com
 
 
 
v.11.19.08