Connecting C2RPS-POE Cable and AC Power Cord
SecureStack C2 Installation Guide  2-7
Connecting C2RPS-POE Cable and AC
 
Power Cord
The C2RPS‐POE is connected to the SecureStack PoE switch using a C2RPS‐POE cable, as 
follows:
1.
Connect one end of the C2RPS‐POE (shown in 
) to the Redundant Power 
Supply connector on the switch device. Then connect the other end to the Redundant 
Power Supply connector at the rear of the C2RPS‐POE as shown in 
 and 
.
2.
Connect a standard AC power cord to the AC input power connector on the 
C2RPS‐POE shown in 
, then plug the AC power cord into the main AC 
power outlet.
3.
The green Power LED on the front of the C2RPS‐POE will glow to indicate a 
successful connection and the C2RPS‐POE is operating properly. If the LED remains 
off, refer to 
 for the recommended action.
4.
If two or more power supplies are being installed, repeat steps 1 through 3 for each 
C2RPS‐POE.
On certain switches, an LED indicator will show that a redundant power supply is 
connected and operating.
.
Table 2-2 C2RPS-POE
 
Status LED Indications and Recommended Actions
LED 
Color 
State
Recommended Action
AC power LED
Green
Solid - AC input to power 
supply is within specifications.
Off - AC input power to power 
supply is out of specification.
None
1. Check AC power cord 
connection to the power 
supply.
2. Check AC power at the power 
outlet. 
3. Swap power cord for a known 
good one.
4. Remove or replace affected 
N-POE PSM.
5. Contact Enterasys Networks 
for support. Refer to
for
 
instructions.
Note: No change in switch configuration is necessary for this installation.