Agilent Technologies 6033A Manuale Utente

Pagina di 134
General Information
12
A fault indicator (FLT) and remote inhibit (INH) circuit provides additional shutdown protection, should either the GP-IB
and/or controller fail.
The FLT circuit provides the user with a means of knowing the status of any unmasked fault register bit independently of
the SRQ function available through the GP-IB. You don’t have to rely on the controller to inform you of a fault within the
power supply.
The INH circuit (which is also independent of the GP-IB) controls the RI bit in the fault registers, and provides a way to
disable the supply remotely (i.e. a "panic button’’).  This gives you a means to bypass the controller and/or GP-IB to disable
the supply.
Safety Considerations
This product is a Safety Class 1 instrument (provided with a protective earth terminal). The instrument and this manual
should be reviewed for safety markings and instructions before operation. Refer to the Safety Summary page at the
beginning of this manual for a summary of general safety information. Safety information for specific procedures is located
at appropriate places in this manual.
Options
Options are standard factory modifications or accessories that are delivered with the supply. The following options are
available. Note lower output power and voltage specifications for Option 100, which is described in Appendix A.
Option
Description
001
Blank Front Panel for line Options 120, 220, and 240 Vdc
100
Input power: 100 Vac + 6%, -10%;
                     48-63 Hz single phase.
120
Input power: 120 Vac +6%, -13%.
                     48-63 Hz single phase.
220
Input Power: 220 Vac +6%, -13%;
                     48-63 Hz, single phase.
240
Input power: 240 Vac +6%, -13%;
                     48-63 Hz, single phase.
800
Rack mount kit for two units side by side
             (Agilent 6033A and Agilent 6038A only)
908
Rack mounting kit
909
Flanges with Handles
Accessories
The System-II cabinet accessories listed below may be ordered with the power supply or separately from your local Agilent
Technologies Sales and Support Office (see list of addresses at rear of this manual).
For 6030A, Agilent 603lA, Agilent 6032A, Agilent 6035A only
Agilent Part No
Description
 5062-3989
Front handle kit for 5-1/4 inch high cabinets
 1460-1345
Tilt stand (1) snaps into standard foot on; must be used in pairs
 5062-3977
Rack flange kit for 5-1/4 inch high cabinet (will be shipped with supply if ordered as
Option 908)
 5062-3983
Rack mount flange kit with handles
0L2
 One additional Operating Manual
0B3
 Service Manual