Toshiba VF-FS1 Manuale Utente

Pagina di 252
E6581381
H-5
8
8.2
Display of trip information
8.2.1      Trip code display
If the inverter trips, an error code is displayed to suggest the cause. Since trip records are retained, information
on each trip can be displayed anytime in the status monitor mode.
Display of trip information
Error code
Failure
code
Description
PGTT
(*)
0000
No error
QE
0001
Overcurrent during acceleration
QE
0002
Overcurrent during deceleration
QE
0003
Overcurrent during constant speed operation
QEN
0004
Load-side overcurrent during start-up
QEC
0005
Armature-side overcurrent during start-up
GRJ
0008
Input phase failure or exhaustion of main circuit capacitor
GRJ
0009
Output phase failure
QR
000A
Overvoltage during acceleration
QR
000B
Overvoltage during deceleration
QR
000C
Overvoltage during constant-speed operation
QN
000D
Inverter overload trip
QN
000E
Motor overload trip
QJ
0010
Overheating trip or thermal detector failure
G
0011
Emergency stop
GGR
0012
E
2
PROM fault 1 (writing error)
GGR
0013
E
2
PROM fault 2 (initialization error) or power-off during the setting of
V[R
GGR
0014
E
2
PROM fault 3 (reading error)
GTT
0015
Inverter RAM fault
GTT
0016
Inverter ROM fault
GTT
0017
CPU fault trip 1
GTT
0018
Communication error
GTT
001A
Current defector fault
GTT
001B
Network error
WE
001D
Small-current trip
WR
001E
Undervoltage trip
QV
0020
Over-torque trip
GH
0022
Ground fault
QER
0025
Overcurrent flowing in element during acceleration
(Continued overleaf)