Toshiba VF-FS1 Manuale Utente
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
E6581381
K-1
11
11.Table of parameters and data
11.1 User parameters
Title
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
HE
Operation frequency of operation
panel
panel
Hz
0.1/0.01
NN
-WN
0.0
3.2
11.2 Basic parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
CWH
-
Wizard function
-
-
The wizard function refers to the
special function of calling up ten
frequently used parameters.
special function of calling up ten
frequently used parameters.
-
4.2.4
6.20.7
CWJ
-
History function
-
-
Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
-
4.2.5
CW
0000
Automatic
acceleration/
deceleration
acceleration/
deceleration
-
-
0: Disabled (manual)
1: Automatic
2: Automatic (only at acceleration)
1: Automatic
2: Automatic (only at acceleration)
0
5.1.1
CW
0040
Parameter setting
macro function
macro function
-
-
0: Disabled
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20 mA current input operation
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20 mA current input operation
0
5.2
EOQF
0003
Command mode
selection
selection
-
-
0: Terminal board
1: Operation panel
2: Serial communication
1: Operation panel
2: Serial communication
0
5.3
7.2
7.2
HOQF
0004
Frequency setting
mode selection 1
mode selection 1
-
-
1: VIA
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
1
5.3
6.5.1
7.1