Troubleshooting Checklist
Troubleshooting
4-5
4.2
TROUBLESHOOTING CHECKLIST
If the 2H253-25R is not working properly, refer to 
causes, and recommended actions to resolve the problem.
Table 4-2
Troubleshooting Checklist 
Problem
Possible Cause
Recommended Action
All LEDs are 
OFF.
Loss of power.
Check for proper connection of the 
power cable and its access to a live 
outlet.
Installed improperly.
Ensure that the 2H253-25R was 
installed properly according to the 
installation instructions in 
No Local 
Management 
Password screen.
Autobaud is enabled, but the 
baud rate has not yet been 
detected.
Press ENTER (RETURN) (may take 
up to four times).
Terminal setup is not correct.
Refer to the SmartSwitch Series 
2E253, 2H252, 2H253, and 2H258 
Local Management User’s Guide
 for 
proper setup procedures.
Improper console cable pinouts.
 for proper 
console port pinouts.
Corrupt firmware image, or 
hardware fault.
If possible, attempt to download the 
image to the 2H253-25R again. Refer 
to 
NVRAM.
Cannot navigate 
beyond Password 
screen.
Improper Community Names 
Table.
1. Refer to the SmartSwitch Series 
2E253, 2H252, 2H253, and 2H258 
Local Management User’s Guide
 for 
the Community Names Table setup.
2. If you have forgotten the 
Community Names, refer to 
to set the mode switch to reset the 
Community Names to their default 
values.