Agilent Technologies 66309B Manuale Utente

Pagina di 190
 
Language Dictionary - 8
103
 
Display Commands
 
Display commands control the front panel display of the dc source. Annunciators are not affected.
 
DISPlay
 
This command turns the front panel display on or off. When off, the front panel display is blank.
 
Command Syntax
 
DISPlay[:WINDow][:STATe] <bool>
 
Parameters
 
0 | 1| OFF| ON
 
*RST Value
 
ON
 
Examples
 
DISP ON     DISPLAY:STATE ON
 
Query Syntax
 
DISPlay[:WINDow][STATe]?
 
Returned Parameters
 
<NR1>   0 or 1
DISPlay:CHANnel
 
Agilent 66309B/D only
Selects the output channel that will be displayed on the front panel. When output 1 is selected, a small
"1" appears in the left-most digit. . When output 2 is selected, a small "2" appears in the left-most digit.
Command Syntax
DISPlay:CHANnel <channel>
Parameters
1 | 2
*RST Value
1
Examples
DISPLAY:CHANNEL 2
Query Syntax
DISPlay:CHANnel?
Returned Parameters
<NR1>   0 or 1
 
DISPlay:MODE
 
Switches the display between its normal instrument functions and a mode in which it displays text sent
by the user. Text messages are defined with the DISPlay:TEXT command.
 
Command Syntax
 
DISPlay[:WINDow]:MODE <mode>
 
Parameters
 
NORMal | TEXT
 
*RST Value
 
NORM
 
Examples
 
DISP:MODE NORM     DISPLAY:MODE TEXT
 
Query Syntax
 
DISPlay[:WINDow]:MODE?
 
Returned Parameters
 
<CRD>     NORMAL or TEXT
 
DISPlay:TEXT
 
This command sends character strings to the display when the display mode is set to TEXT. The
character string is case-sensitive and must be enclosed in either single (‘) or double (“) quotes. The
display is capable of showing up to 14 characters. Strings exceeding 14 characters will be truncated.
 
Command Syntax
 
DISPlay[:WINDow]:TEXT [:DATA] <display_string>
 
Parameters
 
<display string>
 
*RST Value
 
" " (null string)
 
Examples
 
DISP:TEXT "DEFAULT_MODE"
 
Query Syntax
 
DISPlay[:WINDow]:TEXT?
 
Returned Parameters
 
<STR> (Last programmed text string)