Agilent Technologies 66309B Manuale Utente

Pagina di 190
Quick Reference - 1
19
Front Panel Menus - At a Glance
ADDRESS 7
Sets the GPIB Address
INTF GPIB
Selects an interface (GPIB | RS232) 
1
BAUDRATE 300
Selects baud rate (300 | 600 | 1200 | 2400 | 4800 | 9600) 
1
PARITY NONE
Selects message parity (NONE | EVEN | ODD | MARK | SPACE) 
1
FLOW NONE
Selects flow control (XON-XOFF | RTS-CTS | DTR-DSR | NONE) 
1
LANG SCPI
Selects language (SCPI | COMP) 
1
REMOTE FP OFF
Enables or disables Agilent 14575A remote front panel (ON | OFF)
ROM: A.00.00
Displays the firmware revision of the instrument
SN:  US12345678
Displays the serial number of the instrument
*RCL 0
Recalls the instrument state
*SAV 0
Saves the present instrument state
ERROR 0
Displays the number of errors in the SCPI error queue
2  
5.000V  0.104A
Toggles the display between output 1 and output 2 (output 2 shown)
12.000V  
0.204A
Measures the output voltage and current (output 1 shown)
12.500V  MAX
Measures the peak output voltage 
2
1.000V  MIN
Measures the minimum output voltage 
2
12.330V  HIGH
Measures the high level of a  voltage pulse waveform 
2
0.080V  LOW
Measures the low level of a  voltage pulse waveform 
2
12.000V  RMS
Measures the rms voltage 
2
0.350A  MAX
Measures the peak output current 
2
0.050A  MIN
Measures the minimum output current 
2
0.400A  HIGH
Measures the high level of a  current pulse waveform 
2
0.012A  LOW
Measures the low level of a  current pulse waveform 
2
0.210A  RMS
Measures the rms current 
2
12.000V DC:DVM
Measures the dc voltage on the DVM input 
3
12.000V RMS:DVM
Measures the rms voltage on the DVM input 
3
VOLT 12.000
VOLT 2.000
Sets the voltage of output 1 on all models
Sets the voltage of output 2 
4
CURR 2.000
CURR 1.000
Sets the current limit of output 1 on all models
Sets the current limit of output 2 
4
Not available
OVERCURRENT
Protection status (example shows overcurrent tripped)
*RST
Places the dc source in the factory-default state
COUPLING ALL
Couples or decouples output 1 and output 2 (NONE or ALL) 
3
TYPE:CAP LOW
Sets the output capacitance compensation (HIGH, H2,  or LOW)
PON:STATE RST
Select the power-on state command (RST or RCL0)
PROT:DLY 0.08
Sets the output protection delay in seconds
RI LATCHING
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
DFI OFF
Sets the discrete fault indicator state  (ON or OFF)
DFI:SOUR OFF
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
PORT RIDFI
Sets the output port functions (RIDFI or  DIGIO)
DIGIO 7
Sets and reads the I/O port value (0 through 7)
SENSE:PROT OFF
Enables or disables the open sense lead detect circuit (ON or OFF)
REL:MODE DD
Sets the relay mode for Option 521 units (DD, HD, DH, or HH) (output 1 shown)
VOLT:PROT 22
Sets the overvoltage protection level
PROT:STAT ON
Enables or disables overvoltage protection (ON or OFF)
CURR:RANG HIGH
Sets the current range (HIGH, LOW, or AUTO) 
2
CURR:DET ACDC
Sets the current measurement detector (ACDC or DC) 
2
TINT 46.8
Sets the time interval for a front panel measurement in seconds
POINT 2048
Sets the buffer size for a front panel measurement
CAL ON
Accesses calibration menu (See Appendix B).
Use              and              to select parameters (table shows factory defaults).       Use              to exit any menu.
1
Not valid for Agilent Model 66309B
2
Not valid for Agilent Model 66111A
3
Only valid for Agilent Model 66309B/D
4
Only valid for Agilent Model 66311D/66309D
Address
ó
ó
Recall
Save
Shift
Error
ó
ó
Shift
Meter
ó
ó
ó
ó
ó
ó
ó
ó
ó
Channel
ó
Shift
Voltage
Protect
Current
Output
ó
ó
ó
ó
ó
ó
ó
ó
ó
ó
ó
Res
OV
Shift
Shift
ó
ó
ó
ó
ó
ó
Shift
Input
ó
ó
Cal
Shift
Meter
È
É
ó
ó