Agilent Technologies 66309B Manuale Utente

Pagina di 190
6 - Introduction to Programming
74
 
Using Device Clear
 
You can send a device clear at any time abort a SCPI command that may be hanging up the GPIB
interface. The status registers, the error queue, and all configuration states are left unchanged when a
device clear message is received. Device clear performs the following actions:
 
The input and output buffers of the dc source are cleared.
 
The dc source is prepared to accept a new command string.
 
The following statement shows how to send a device clear over the GPIB interface using Agilent BASIC:
 
CLEAR 705
IEEE-488 Device Clear
 
The following statement shows how to send a device clear over the GPIB interface using the GPIB
command library for or QuickBASIC:
 
IOCLEAR (705)
SCPI Conformance Information
SCPI Conformed Commands
The Agilent 66111A, 66311B/D, and 66309B/D conform to SCPI Version 1995.0.
ABOR
OUTP:PROT:DEL
STAT:QUES:ENAB
CAL:DATA
OUT:PROT:STAT
STAT:QUES:NTR
CAL:STAT
[SOUR]:CURR[:LEV][:IMM][:AMPL]
STAT:QUES:PTR
DISP[:WIND][:STAT]
[SOUR]:CURR[:LEV]:TRIG[:AMPL]
SYST:ERR?
DISP[:WIND]:TEXT[:DATA]
[SOUR]:CURR:PROT:STAT
SYST:LANG
INIT[:IMM]:SEQ | NAME
[SOUR]:VOLT[:LEV][:IMM][:AMPL]
SYST:VERS?
INIT:CONT:SEQ | NAME
[SOUR]:VOLT[:LEV]:TRIG[:AMPL]
TRIG[:SEQ1 | :TRAN][:IMM]
MEAS | FETC:ARR:CURR[:DC]?
[SOUR]:VOLT:PROT
TRIG[:SEQ1 | :TRAN]:SOUR
MEAS | FETC:ARR:VOLT[:DC]?
SENS:CURR[:DC]:RANG[:UPP]
TRIG:SEQ2 | ACQ[:IMM]
MEAS | FETC[:SCAL]:CURR[:DC]?
SENS:FUNC
TRIG:SEQ2 | ACQ:SOUR
MEAS | FETC[:SCAL]:CURR:HIGH?
SENS:SWE:OFFS:POIN
TRIG:SEQ:DEF
MEAS | FETC[:SCAL]:CURR:LOW?
SENS:SWE:POIN
*CLS
MEAS | FETC[:SCAL]:CURR:MAX?
SENS:SWE:TINT
*ESE*ESE?*ESR?
MEAS | FETC[:SCAL]:CURR:MIN?
STAT:OPER[:EVEN]?
*IDN?
MEAS | FETC[:SCAL]:VOLT[:DC]?
STAT:OPER:COND?
*OPC*OPC?*OPT?
MEAS | FETC[:SCAL]:VOLT:HIGH?
STAT:OPER:ENAB
*PSC*PSC?
MEAS | FETC[:SCAL]:VOLT:LOW?
STAT:OPER:NTR
*RCL*RST
MEAS | FETC[:SCAL]:VOLT:MAX?
STAT:OPER:PTR
*SAV*SRE*STB?
MEAS | FETC[:SCAL]:VOLT:MIN?
STAT:PRES
*TRG*TST?
OUTP[:STAT]
STAT:QUES[:EVEN]?
*WAI
OUTP:PROT:CLE
STAT:QUES:COND?
Non-SCPI Commands
CAL:CURR[:SOUR][:DC][:POS]
OUTP:DFI[:STAT]
CAL:CURR[:SOUR][:DC]:NEG
OUTP:DFI:SOUR
CAL:MEAS[:DC]:LOWR
OUTP:PON:STAT
CAL:MEAS:AC
OUTP:RI:MODE
CAL:LEV
OUTP:TYPE
CAL:PASS
SENS:CURR:DET
CAL:SAVE
[SOUR]:DIG:DATA[:VAL]
CAL:VOLT[:DC]
[SOUR]:DIG:FUNC
CAL:VOLT:PROT
TRIG:SEQ2 | ACQ:COUN:CURR | :VOLT
DISP[:WIND]:MODE
TRIG:SEQ2 | ACQ:HYST:CURR | :VOLT
MEAS | FETC[:SCAL]:CURR:ACDC?
TRIG:SEQ2 | ACQ:LEV:CURR | :VOLT
MEAS | FETC[:SCAL]:VOLT:ACDC?
TRIG:SEQ2 | ACQ:SLOP:CURR | :VOLT