Installing the Device
Installation
3-7
Figure 3-4
Installing the Device in a Rack
3.3.3
Connecting Power
To connect the 2H258-17R to the power sources, proceed as follows: 
1. Plug each power cord into a grounded wall outlet, see 
. To take advantage of the load 
sharing and redundancy capabilities, each power cord must be plugged into a separate dedicated 
ac outlet. The POWER (PWR) LED turns ON (green) and the CPU LED alternates between 
green and amber during boot up. It takes approximately one minute for the 2H258-17R to boot 
up.
NOTE: The two power supplies in the 2H258-17R have automatic voltage sensing that 
allows connection to power sources ranging from 100–125 Vac, 2.5 A or 200–240 Vac, 
1.25 A, 50/60 Hz. 
NOTE: If the power-up sequence is interrupted on this device, or if optional hardware 
has been installed or removed, this device may run an extended diagnostics sequence 
that may take up to five minutes to complete.