Generac RTS12EZA1 Dépliant

Pagina di 2
Model
RTS10EZA1
RTS12EZA1
RTS14EZA1
RTS16EZA1
Voltage
240, 1ø
240, 1ø
240, 1ø
240, 1ø
Circuits***50A, 240V
1
40A, 240V
1
1
1
30A, 240V
1
1
20A, 240V
1
1
1
20A, 120V
3
3
6
5
15A, 120V
3
5
4
5
Phase
1
Rated AC Frequency
60 Hz
Enclosure Material
Steel
Enclosure Type
NEMA 1
Unit Weight (lbs./kilos)
57/25.9
60.8/27.5
64/29
68/30.8
Withstand Rating (Amps)
10,000
Lug Range
2/0 - #14
Load Transition Type
Open Transition
Wire Gauge (Hot, Neutral, Ground, Control)
10, 10, 10, 18
8, 8, 10, 18
6, 6, 8, 18
6, 6, 8, 18
FUNCTIONS
Generac EZ Switch™
All Timing and sensing functions originate in the generator controller
 
Utility voltage drop-out ......................................................................................................................................................................................................................<60%
 
Timer to generator start ...................................................................................................................................... 10 second factory set, adjustable between 10-30 seconds
 
Engine warm up delay .................................................................................................................................................................................................................5 seconds
 
Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds
 
Utility voltage pickup .........................................................................................................................................................................................................................>80%
 
Re-transfer time delay ...............................................................................................................................................................................................................15 seconds
 
Engine cool-down timer ............................................................................................................................................................................................................60 seconds
 Exerciser 
 .............................................................................................................................................................................................................. 12 minutes every 7 days
 
The transfer switch can be operated manually without power applied.
SPECIFICATIONS
®
Generac Power Systems, Inc. • S45 W29290 HWY. 59,  Waukesha, WI 53189 • generac.com
©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0186640SBY-D / Printed in U.S.A. 02/17/12
EZ Switch™ Features
• Electrically operated, mechanically-held contacts for fast, positive connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 1 (indoor rated) enclosure is standard on the 100 amp switch.
• 2 Year Limited Warranty
Mechanical Dimensions (in inches/mm)
Current 
Rating
No. of 
Poles
Height
Width
Depth
H1
H2
W1
W2
7/177.8
100 UL Listed
2
26.5/673.1 29.25/742.9 8.14/206.7 12.5/317.5
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
Neutral Lug/Stud
Ground Lug
100A 2-Pole UL
1 x 1/0-12
1 x 3/8-16 Stud
1 x 2/0-14
731.9
[28.8]
637.6
[25.1]
LEFT SIDE VIEW
642
[25.3]
76.2 [3.0]
PEA GRAVEL
MINIMUM
TRANSFER 
SWITCH
8KW - 17KW
(IF SUPPLIED)
TRANSFER 
SWITCH
20KW
(IF SUPPLIED)
1218
[47.9]
FRONT VIEW
1226
[48.3]
H2
H1
W1
W2
H2
H1
W1
W2
®