Fujitsu RX600 S6 Manuale Utente

Pagina di 134
100
Operating Manual
 RX600 
S6
CSS components
If you want to remove an HDD/SSD module during operation, proceed as 
follows:
Ê
If you want to remove an HDD/SSD module that is not defective, the drive 
must be first set to "Offline" via the software (RAID controller configuration 
software).
Ê
Unlock the HDD/SSD module as described in section 
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait for at least 60 seconds. 
I
This period is necessary for the RAID controller to recognize that an 
HDD/SSD module has been removed and for the hard disk drive to 
come to a stop.
Ê
Pull the HDD/SSD module out completely.
Ê
Install the new HDD/SSD module, as described in 
.
V
CAUTION!
If you have removed an HDD/SSD module and do not install a new 
one in its place, put the dummy module back in its place for cooling, 
to comply with EMC regulations (regulations regarding 
electromagnetic compatibility), and for protection against fire. Ensure 
that the dummy module engages correctly in the bay.