Lucent Technologies 555-233-115 Manuale Utente

Pagina di 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory 
3-48
Release 5/6si to Release 8r 
3
Reboot the System
1. Connect the management terminal to the TERMINAL connector on the rear 
of PPN control carrier “A,” or install the G3-MA according to 
DEFINITY 
Communications System Generic 3 Management Applications 
 
Operations, 585-229-202.
2. Insert the new Release 8r system removable media in the optical drive.
3. Behind each EPN cabinet, set the circuit breaker to ON.
4. At the PPN power distribution unit, set the main circuit breaker to ON.
5. The system performs a reset level 4 rebooting process, loading blank 
translations from the disk. Rebooting takes 5 to 11 minutes.
6. Type reset system 4 and press 
Enter
. This instructs the system to perform 
a reset level 4 rebooting process, loading the upgraded STS translations 
from the new removable media. Rebooting takes 5 to 11 minutes.
7. Log in as craft at the 
login:
 prompt on the terminal and set the time to 
ensure the system is booted properly.
8. After about 2 minutes, type status spe and press 
Enter
. The 
standby 
handshake
 field must be 
up
 before continuing with the upgrade.
9. Type reset spe standby 4 and press 
Enter
. This changes the standby SPE 
to active and vice versa. This takes about 10 minutes.
10. If the system is high or critical reliability, type status spe and press 
Enter
The 
handshake
refresh
, and 
shadowing
 fields must be 
up
 before 
continuing with the upgrade. Also, the standby side must be 
in-service
. The heartbeat on the standby SPE flashes yellow.
11. Type restore disk
 [
spe-a
 or 
both
full and press 
Enter
. This instructs 
the system to write the upgraded STS translation information from memory 
to the disk(s).
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway. 
2. When the main menu appears, select 
Maintenance.
3. Select 
Reset System from the Maintenance menu.
4. Select 
Restart System from the Reset System menu.
Label Main Distribution Frame
1. Label the MDF with the new PN number of the Release 8r EPN. The STS 
software upgrade assigns the next PN number, after the highest 
numbered PN in the Release 5/6si system, to the upgraded EPN.