Timing Analysis 
 
Installation Quick 
Reference 
The following procedure describes the major steps required to 
perform timing analysis measurements with the PCI Active 
Analysis Probe module.   
1.  Set the State/Timing switch to TIMING.  The State LED 
will be doused.  See page 10 of this manual for details 
on the front panel switches. 
2.  After removing the probe tip assemblies, plug the logic 
analyzer cables into the Analysis Probe cable headers.  
See pages 12 and 13 of this manual for details. 
3.  Power down the PCI target.  Install the PCI Active 
Analysis Probe module into a slot in the non-powered 
target PCI Local bus.  Then power up the target. 
4.  Load the logic analyzer configuration file by loading the 
appropriate file from the Analysis Probe interface 
diskette.  See pages 16  and 17 of this manual for 
details. 
 
Timing Mode Skew 
Since the PCI Active Analysis Probe contains active input  
buffers it introduces skew to the PCI Local Bus signals.  The 
skew is as follows: 
•  Any PCI bus signal to the PCI clock  -1.0 to +2.3ns 
maximum 
•  Any PCI bus signal to any other PCI bus signal 2.1ns 
maximum 
                                                                         33