1655x,1670/71 P32D_55
32 bit Demultiplexed  - Analysis Probe PODS 
1-6  connect to PODS 1-4  on the Master 
card and 1-2 on the Slave card 1-2 
respectively (PODS 1-6 on the 1670/71) 
1655x,1670 P64M_55
64-bit Multiplexed - Analysis Probe PODS 1-
4,7,8,11 connect to Logic Analyzer PODS 
1-4 on the Master card and PODS 1-3 on 
the Slave Card respectively (PODS 1-7 
on the \1670) 
 1655x 
P64D_55
64 bit Demultiplexed - Analysis Probe PODS 
1-11 connect to Logic Analyzer PODS  1-
4 on the Master card, 1-4 on the lower 
slave card (positioned below the master 
card in the mainframe) and PODS 1-3 on 
the slave card positioned above the 
master card in the mainframe respectively 
1655x P64AD55
32 bit address Demultiplexed and 64 bit data 
Analysis Probe PODS 1-6,7,8 and 11 to 
Logic Analyzer PODS 1-4 on the Master 
card, 1-4 on the lower slave card 
(positioned below the master card in the 
mainframe) and POD 1 on the slave card 
positioned above the master card in the 
mainframe respectively 
 
The PCI Inverse 
Assembler 
The PCI Active Analysis Probe Inverse Assembler file IAP64E is 
automatically loaded into the logic analyzer when the 
configuration file is loaded.  If the Inverse Assembler does not 
appear on the state listing screen select the base of the label 
DATA.  From the menu that appears select INVASM.  The 
Inverse Assembler is only for use in state mode. 
 
 
 
The Format Menu 
The PCI Active Analysis Probe diskette sets up the format menu 
to include all of the signals that are presented to the logic 
analyzer.  This format is the same for both Timing and State 
Analysis.  the labels STAT, DATA , DATA_B, ADDR and 
ADDR_B are required in order run the Inverse Assembler.  They 
should not be changed or deleted. 
                                                                         17